310 Plant Analytical Tests This method quantitatively determines the concentration of aluminum in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by inductively coupled plasma mass spectrometry (ICP-MS). The method detection limit is approximately 0.01 mg/kg. Al. |
335 Plant Analytical Tests This method determines the concentration of ammonium-nitrogen in botanical materials. It is determined spectrophotometrically. The method detection limit is approximately 10 mg/kg (sample dry basis) and is generally reproducible to within ± 10.0%. NH4-N. |
311 Plant Analytical Tests This method quantitatively determines the concentration of arsenic in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by vapor generation inductively coupled plasma (VG-ICP). The method detection limit is approximately 0.05 ppm. As. |
312 Plant Analytical Tests This method quantitatively determines the concentration of barium in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Ba. |
313 Plant Analytical Tests This method quantitatively determines the concentration of boron in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. B. |
314 Plant Analytical Tests This method quantitatively determines the concentration of cadmium in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Cd. |
315 Plant Analytical Tests This method quantitatively determines the concentration of calcium in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.02%. Ca. |
Cannabinoid ⋅ Plant Analytical Tests This testing provides plant tissue testing for total THC, total CBD, d9-THC, THCa, CBD, CBDa, CBN, CBDv, d8-THC, THCv, CBG, CBGa and CBC. Ajwa labs is ISO 17025 certified and qualified for regulatory testing samples. |
316 Plant Analytical Tests This method quantitatively determines the concentration of carbon in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. C. |
336 Plant Analytical Tests This method determines the concentration of chloride in botanical materials. It is determined by coulometric titration or ion selective electrode. The method detection limit is approximately 10 mg/kg (sample dry basis) and is generally reproducible to within ± 10.0%. Cl. |
317 Plant Analytical Tests This method quantitatively determines the concentration of chromium in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Cr. |
318 Plant Analytical Tests This method quantitatively determines the concentration of cobalt in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Co. |
343 Plant Analytical Tests This package determines the macro nutrient content and moisture percentage of a compost or manure sample. C, N, P, K, % Moisture, C:N Ratio. |
344 Plant Analytical Tests This is a combined package to determine the fertility profile of a compost or manure sample. C, N, P, K, % Moisture, C:N Ratio, Ca, Mg, S, B, Cu, Fe, Mn, Zn, Na, Cl |
345 Plant Analytical Tests This test determines the moisture percentage in a manure or compost sample. % Moisture. |
346 Plant Analytical Tests This is a a comprehensive combined package for a full compost or manure profile. pH (water 1:5), EC (Water 1:5),C, N, P, K, % Moisture, C:N Ratio, Ca, Mg, S, B, Cu, Fe, Mn, Zn, Na, Cl. |
319 Plant Analytical Tests This method quantitatively determines the concentration of copper in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Cu. |
301 Plant Analytical Tests This is a tissue or petiole analysis for nitrate, phosphate, and potassium. NO3-N, PO4-P, K. |
302 Plant Analytical Tests This is a tissue or petiole analysis for nitrate, phosphate, ammonium and potassium. NO3-N, NH4-N, PO4-P, K. |
303 Plant Analytical Tests This is a combined extractable nutrients test including sodium and chlorine. NO3-N,PO4-P, SO4-S, K, Ca, Mg, S, B, Cu, Fe, Mn, Zn, Na, Cl |
320 Plant Analytical Tests This method quantitatively determines the concentration of iron in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Fe. |
321 Plant Analytical Tests This method quantitatively determines the concentration of lead in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Pb. |
322 Plant Analytical Tests This method quantitatively determines the concentration of magnesium in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.02%. Mg. |
323 Plant Analytical Tests This method quantitatively determines the concentration of manganese in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Mn. |
324 Plant Analytical Tests This method quantitatively determines the concentration of molybdenum in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Mo. |
325 Plant Analytical Tests This method quantitatively determines the concentration of nickel in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.5 mg/kg. Ni. |
337 Plant Analytical Tests This method determines the concentration of nitrate-nitrogen in botanical materials. It is determined spectrophotometrically. The method detection limit is approximately 10 mg/kg (sample dry basis) and is generally reproducible to within ± 10.0%. NO3-N. |
326 Plant Analytical Tests This method quantitatively determines the concentration of nitrogen in botanical materials utilizing a nitric-perchloric acid digestion. Digest analyte concentrations are determined by atomic absorption spectrometry (AAS) and/or inductively coupled plasma atomic emission spectrometry (ICP-AES). The method detection limit is approximately 0.02%. N. |
308 Plant Analytical Tests This a combined nutrient test for nitrogen, phosphorus, potassium, magnesium, sulfur, boron, copper, iron, manganese, zinc, sodium and chlorine. N, P, K, Ca, Mg, S, B, Cu, Fe, Mn, Zn, Na, Cl. |
304 Plant Analytical Tests This package is a combination test for nitrogen, phosphorus and potassium. N, P, K. |
Plant Analytical Tests